Accreditations

CERTIFICATE DNV - UNI EN ISO 9001:2000
Certifies according to regulation ISO 9001:2000 that the firm works in compliance with all processes related to quality control.
In particular, Aliva S.r.l. is certified for the “design, production and installation of ventilated facades”.

CERTIFICATE SOA Alpi Professional (Società Organismo di Attestazione)
Certifies according to DPR 34/00 the existence of the technical, financial and managerial requirements for entrusting public works by bodies that hold tender calls.
Certification

CERTIFICATE IST. GIORDANO:
CORROSION OF ALUMINIUM ALLOY AND STAINLESS STEEL STRUCTURE TEST
Ventilated wall tested for resistance to corrosion - to regulation UNI ISO 9227.
Lab test to measure metal components of a Ventilated Facade (in anodised and non-anodised aluminium alloy) with porcelain tile cladding, to determine the resistance in extreme conditions.
The results show the sample does not alter to compromise the mechanical and structural characteristics.

CERTIFICATE IST. GIORDANO: ACOUSTICS TEST
Ventilated wall soundproofed - to regulation UNI EN ISO 140/3 and UNI EN ISO 717/1.
Lab test determines the soundproofing properties of a Ventilated Facade with porcelain tile
and natural stone facings (with insulating panels in fibreglass.)
Results prove the sample to provide outstanding soundproofing benefits.

CERTIFICATE IST. GIORDANO: ALI Q - PRESSURE AND DEPRESSURISATION
Ventilated wall tested for wind resistance.
Lab test performed with the pressure and depressurisation of a portion of a Ventilated Facade with ALI Q structure (and slabs of porcelain tile 60x80 cm fixed horizontally).
Results prove the sample resisted to a pressure and a depressurisation equal to 4500 Pa. without any distortion or tearing.

CERTIFICATE IST. GIORDANO: ALI SR - PRESSURE AND DEPRESSURISATION
Ventilated wall tested for wind resistance.
Lab test performed with the pressure and depressurisation of a portion of a Ventilated Facade with ALI SR structure (and slabs of porcelain tile 60x80 cm fixed horizontally.)
Results prove the sample resisted to a pressure and depressurisation equal to 4000 Pa. without any distortion or tearing.

CERTIFICATE IST. GIORDANO: FLAME RESISTANCE OF ALI FIRE COMPONENTS
Ventilated wall (with the ALI FIRE system) tested for flame resistance - to regulation UNI EN 1363-1 of 2001.
Lab test to determine fire resistance of ventilated facade with porcelain tile cladding (with Ali-Fire system fireproofing)
Results prove the ALI FIRE facade delays the spreading of flames and smoke along the facade.
CERTIFICATE IST. GIORDANO: RESISTANCE TO WIND
Wind gust resistance test on a ventilated wall with porcelain tile cladding
CERTIFICATE IST. GIORDANO: ALI Q - SOFT BODY IMPACT
Ventilated wall soft body shock tested.
Lab test determines the resistance of a Ventilated Facade (with porcelain tile cladding), hit by a soft object.
Results prove the sample resisted impacts of considerable strength.